{"id":19,"date":"2023-10-25T13:09:26","date_gmt":"2023-10-25T13:09:26","guid":{"rendered":"https:\/\/meniconbloom.com\/uk\/?page_id=19"},"modified":"2024-10-08T13:52:31","modified_gmt":"2024-10-08T13:52:31","slug":"menicon-bloom-day","status":"publish","type":"page","link":"https:\/\/meniconbloom.com\/uk\/professionals\/menicon-bloom-day\/","title":{"rendered":"Menicon Bloom Day: a soft daily lens for myopia management"},"content":{"rendered":"<section id=\"section-2-40\" class=\" ct-section\" style=\"background-image:url(https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/2023\/07\/Menicon-Bloom-Day-1.png);background-size: cover;\" ><div class=\"ct-section-inner-wrap\"><h1 id=\"headline-3-40\" class=\"ct-headline\">Menicon Bloom Day\u2122 lenses&nbsp;<br>Your soft daily option<\/h1><\/div><\/section><section id=\"section-4-40\" class=\" ct-section\" ><div class=\"ct-section-inner-wrap\"><div id=\"div_block-47-40\" class=\"ct-div-block\" ><h2 id=\"headline-46-40\" class=\"ct-headline\">Menicon Bloom Day\u2122<\/h2><div id=\"_rich_text-5-40\" class=\"oxy-rich-text\" >Insipired by advanced camera optics, Menicon Bloom Day<sup>TM<\/sup> with its exclusive <strong>Neurofocus Optics<sup>\u00ae<\/sup><\/strong>\u00a0technology uses an extended depth of focus design to provide a smooth transition in refractive power from a central zone that provides sharp distance vision to a peripheral zone that generates relative plus power.<\/div><\/div><div id=\"code_block-53-40\" class=\"ct-code-block\" ><video controls width=\"100%\">\n  <source src=\"\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/MBD_edof_pinhole.mp4\">\n<\/video><\/div><div id=\"new_columns-7-40\" class=\"ct-new-columns\" ><div id=\"div_block-8-40\" class=\"ct-div-block\" ><div id=\"_rich_text-12-40\" class=\"oxy-rich-text\" ><p>The Menicon Bloom Day<sup>TM<\/sup> features one universal lens design for optimal fit efficiency, with a <strong>rapid, continuous, and uninterrupted progression in plus power<\/strong>. As such the lens power at the edge of a child\u2019s pupil, estimated at 5 mm, would be approximately +6.00\/+8.00D of relative plus power, building in 5-micron steps from the center of the lens design<sup>1,2<\/sup>. This creates significant peripheral myopic defocus that provides clinically relevant levels of myopia control efficacy compared to other center-distance multifocal contact lens designs.<sup>3-6<\/sup><\/p><p>High Add powers have been shown to create a significant relative myopic shift in peripheral refraction relative to central refraction.<sup>7<\/sup><\/p><\/div><\/div><div id=\"div_block-9-40\" class=\"ct-div-block\" ><div id=\"div_block-61-40\" class=\"ct-div-block\" ><img decoding=\"async\"  id=\"image-62-40\" alt=\"\" src=\"https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/10\/MBD-new-image-3.png\" class=\"ct-image\" srcset-disabled=\"https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/10\/MBD-new-image-3.png 1574w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/10\/MBD-new-image-3-300x250.png 300w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/10\/MBD-new-image-3-1024x854.png 1024w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/10\/MBD-new-image-3-768x641.png 768w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/10\/MBD-new-image-3-1536x1281.png 1536w\" sizes=\"(max-width: 1574px) 100vw, 1574px\" \/><div id=\"_rich_text-65-40\" class=\"oxy-rich-text\" >In-vitro power profile map of Menicon\u00a0Bloom DayTM wavefront error and optical power were measured using a single-pass aberrometer with\u00a0the highest resolution\u00a0Shack-Hartmann wavefront sensor by\u00a0Wavefront Dynamics.<\/div><\/div><div id=\"div_block-66-40\" class=\"ct-div-block\" ><img decoding=\"async\"  id=\"image-67-40\" alt=\"\" src=\"https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/10\/MBD-new-image-4.png\" class=\"ct-image\" srcset-disabled=\"https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/10\/MBD-new-image-4.png 1574w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/10\/MBD-new-image-4-300x250.png 300w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/10\/MBD-new-image-4-1024x854.png 1024w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/10\/MBD-new-image-4-768x641.png 768w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/10\/MBD-new-image-4-1536x1281.png 1536w\" sizes=\"(max-width: 1574px) 100vw, 1574px\" \/><div id=\"_rich_text-68-40\" class=\"oxy-rich-text\" >The catenary power profile is highly aspheric and can be represented by multiple orders of spherical aberrations. The high magnitude of spherical aberrations are responsible for the extended depth of focus in image space.<\/div><\/div><\/div><\/div><div id=\"new_columns-69-19\" class=\"ct-new-columns\" ><div id=\"div_block-70-19\" class=\"ct-div-block\" ><img decoding=\"async\"  id=\"image-73-19\" alt=\"\" src=\"https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/1_EN.png\" class=\"ct-image\" srcset-disabled=\"https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/1_EN.png 2160w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/1_EN-300x300.png 300w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/1_EN-1024x1024.png 1024w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/1_EN-150x150.png 150w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/1_EN-768x768.png 768w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/1_EN-1536x1536.png 1536w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/1_EN-2048x2048.png 2048w\" sizes=\"(max-width: 2160px) 100vw, 2160px\" \/><\/div><div id=\"div_block-71-19\" class=\"ct-div-block\" ><img decoding=\"async\"  id=\"image-74-19\" alt=\"\" src=\"https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/6_EN.png\" class=\"ct-image\" srcset-disabled=\"https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/6_EN.png 2160w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/6_EN-300x300.png 300w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/6_EN-1024x1024.png 1024w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/6_EN-150x150.png 150w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/6_EN-768x768.png 768w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/6_EN-1536x1536.png 1536w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/08\/6_EN-2048x2048.png 2048w\" sizes=\"(max-width: 2160px) 100vw, 2160px\" \/><\/div><\/div><div id=\"text_block-76-19\" class=\"ct-text-block\" >During the Protect study, the Menicon Bloom Day\u2122 lenses were worn for 11-12 hours per day; the wearing time was higher compared to the study protocol, which indicated 10 hours per day and six days per week.<br><\/div><img decoding=\"async\"  id=\"image-72-19\" alt=\"\" src=\"https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/10\/ENGLISH.png\" class=\"ct-image\" srcset-disabled=\"https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/10\/ENGLISH.png 6000w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/10\/ENGLISH-300x169.png 300w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/10\/ENGLISH-1024x576.png 1024w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/10\/ENGLISH-768x432.png 768w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/10\/ENGLISH-1536x864.png 1536w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2024\/10\/ENGLISH-2048x1152.png 2048w\" sizes=\"(max-width: 6000px) 100vw, 6000px\" \/><\/div><\/section><section id=\"section-29-40\" class=\" ct-section\" ><div class=\"ct-section-inner-wrap\"><div id=\"div_block-30-40\" class=\"ct-div-block\" ><div id=\"fancy_icon-31-40\" class=\"ct-fancy-icon\" ><svg id=\"svg-fancy_icon-31-40\"><use xlink:href=\"#FontAwesomeicon-quote-left\"><\/use><\/svg><\/div><h2 id=\"headline-32-40\" class=\"ct-headline\">It\u2019s magic to children,<br>science to grown-ups<br><\/h2><div id=\"fancy_icon-33-40\" class=\"ct-fancy-icon\" ><svg id=\"svg-fancy_icon-33-40\"><use xlink:href=\"#FontAwesomeicon-quote-right\"><\/use><\/svg><\/div><\/div><\/div><\/section><section id=\"section-43-40\" class=\" ct-section\" ><div class=\"ct-section-inner-wrap\"><img decoding=\"async\"  id=\"image-45-40\" alt=\"\" src=\"https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/07\/Menicon-Bloom-Day-1.png\" class=\"ct-image\" srcset-disabled=\"https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/07\/Menicon-Bloom-Day-1.png 1920w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/07\/Menicon-Bloom-Day-1-300x180.png 300w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/07\/Menicon-Bloom-Day-1-1024x614.png 1024w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/07\/Menicon-Bloom-Day-1-768x461.png 768w, https:\/\/meniconbloom.com\/uk\/wp-content\/uploads\/sites\/22\/2023\/07\/Menicon-Bloom-Day-1-1536x922.png 1536w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><\/div><\/section><section id=\"section-34-40\" class=\" ct-section\" ><div class=\"ct-section-inner-wrap\"><div id=\"new_columns-35-40\" class=\"ct-new-columns\" ><div id=\"div_block-36-40\" class=\"ct-div-block\" ><h2 id=\"headline-37-40\" class=\"ct-headline\">Everything you need to offer myopia control safely and effectively.<\/h2><div id=\"_rich_text-38-40\" class=\"oxy-rich-text\" ><p>If you want to become a Menicon Bloom\u2122 fitter, please contact us.<\/p><\/div><\/div><div id=\"div_block-39-40\" class=\"ct-div-block\" ><a id=\"link_button-40-40\" class=\"ct-link-button\" href=\"http:\/\/\"   >Contact us<\/a><\/div><\/div><\/div><\/section><section id=\"section-48-40\" class=\" ct-section\" ><div class=\"ct-section-inner-wrap\"><div id=\"_toggle-49-40\" class=\"oxy-toggle toggle-6463 toggle-6463-expanded\"  data-oxy-toggle-initial-state=\"closed\" data-oxy-toggle-active-class=\"toggle-6463-expanded\" >\n\t\t\t<div class='oxy-expand-collapse-icon' href='#'><\/div>\n\t\t\t<div class='oxy-toggle-content'>\n                <h6 id=\"headline-50-40\" class=\"ct-headline\">References<\/h6>\t\t\t<\/div>\n\t\t<\/div><div id=\"div_block-51-40\" class=\"ct-div-block\" ><div id=\"_rich_text-52-40\" class=\"oxy-rich-text \" ><p>&nbsp;<\/p>\n<ol>\n<li>Cooper J, O'Connor B, Aller T, Dillehay SM, Weibel K, Benoit D. Reduction of myopic progression using a multifocal soft contact lens: a retrospective cohort study.&nbsp;Clin Ophthalmol. 2022;16:2145-2155. doi:<a href=\"http:\/\/10.2147\/OPTH.S370041\">10.2147\/OPTH.S370041<\/a><\/li>\n<li>Tuan KA, Dillehay SM, a Randomized Controlled Trial for Myopia Progression Control Using Catenary Power Profile Contact Lenses: 12-month Effectiveness and Safety. Investigative Ophthalmology &amp; Visual Science, 2024;65(7):2697<\/li>\n<li>Gifford KL, Richdale K, Kang P, et al. IMI - Clinical management guidelines report.&nbsp;Invest Ophthalmol Vis Sci. 2019;60(3):M184-M203. doi:<a href=\"http:\/\/10.1167\/iovs.18-25977\">10.1167\/iovs.18-25977<\/a><\/li>\n<li>Smith EL 3rd. Optical treatment strategies to slow myopia progression: effects of the visual extent of the optical treatment zone.&nbsp;Exp Eye Res. 2013;114:77-88. doi:<a href=\"http:\/\/10.1016\/j.exer.2012.11.019\">10.1016\/j.exer.2012.11.019<\/a><\/li>\n<li>Lee R, Achenbach P, Schwiegerling J. Instantaneous power profiles vs sagittal power profiles of various center distance multifocal lenses. Optom Vis Sci. 2019;96:E-abstract 195249.<\/li>\n<li>Yu Z, Zhong A, Zhao X, Li D, Duan J. Efficacy and safety of different add power soft contact lenses on myopia progression in children: a systematic review and meta-analysis.&nbsp;Ophthalmic Res. 2022;65(4):398-416. doi:<a href=\"http:\/\/10.1159\/000523675\">10.1159\/000523675<\/a><\/li>\n<li>Lopes-Ferreira D, Ribeiro C, Neves H, et al. Peripheral refraction with dominant design multifocal contact lenses in young myopes. J Optom. 2013;6(2):85-94. doi:<a href=\"https:\/\/doi.org\/10.1016%2Fj.optom.2013.01.001\" target=\"_blank\" rel=\"noopener noreferrer\">10.1016\/j.optom.2013.01.001<\/a><\/li>\n<\/ol><\/div><\/div><\/div><\/section>            <div tabindex=\"-1\" class=\"oxy-modal-backdrop center \"\n                style=\"background-color: rgba(0,0,0,0.5);\"\n                data-trigger=\"user_clicks_element\"                data-trigger-selector=\"#link_button-40-40\"                data-trigger-time=\"5\"                data-trigger-time-unit=\"seconds\"                data-close-automatically=\"no\"                data-close-after-time=\"10\"                data-close-after-time-unit=\"seconds\"                data-trigger_scroll_amount=\"50\"                data-trigger_scroll_direction=\"down\"\t            data-scroll_to_selector=\"\"\t            data-time_inactive=\"60\"\t            data-time-inactive-unit=\"seconds\"\t            data-number_of_clicks=\"3\"\t            data-close_on_esc=\"on\"\t            data-number_of_page_views=\"3\"                data-close-after-form-submit=\"no\"                data-open-again=\"always_show\"                data-open-again-after-days=\"3\"            >\n\n                <div id=\"modal-54-40\" class=\"ct-modal\" ><a id=\"link-55-40\" class=\"ct-link oxy-close-modal\" href=\"http:\/\/\" target=\"_self\"  ><div id=\"fancy_icon-56-40\" class=\"ct-fancy-icon\" ><svg id=\"svg-fancy_icon-56-40\"><use xlink:href=\"#FontAwesomeicon-close\"><\/use><\/svg><\/div><\/a><div id=\"code_block-57-40\" class=\"ct-code-block\" ><iframe loading=\"lazy\" src=\"https:\/\/us2.list-manage.com\/contact-form?u=7318fccb50f49e8f7f9b9a308&form_id=226cc5eba589f3b9a14094a4918e874a\" width=\"100%\" height=\"100%\" style=\"border:none;\"><\/iframe>\n<\/div><\/div>\n            <\/div>\n        ","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":15,"menu_order":14,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-19","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/meniconbloom.com\/uk\/wp-json\/wp\/v2\/pages\/19","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/meniconbloom.com\/uk\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/meniconbloom.com\/uk\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/meniconbloom.com\/uk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/meniconbloom.com\/uk\/wp-json\/wp\/v2\/comments?post=19"}],"version-history":[{"count":3,"href":"https:\/\/meniconbloom.com\/uk\/wp-json\/wp\/v2\/pages\/19\/revisions"}],"predecessor-version":[{"id":441,"href":"https:\/\/meniconbloom.com\/uk\/wp-json\/wp\/v2\/pages\/19\/revisions\/441"}],"up":[{"embeddable":true,"href":"https:\/\/meniconbloom.com\/uk\/wp-json\/wp\/v2\/pages\/15"}],"wp:attachment":[{"href":"https:\/\/meniconbloom.com\/uk\/wp-json\/wp\/v2\/media?parent=19"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}